Recommended Practices are only less mandatory than Standards by virtue of their slightly less critical subject matter and/or the fact that deviation for specific reason is permissible.
NOTE: Common rail is NOT compatible with NTRAK wiring specifications. Check the S.I.G. for your particular scale for further details.
NOTE: S scale wiring is entirely different. Check NASG module specs for details.
THE DRAWING BELOW COURTESY OF NTRAK. CHECK SIG FOR YOUR SCALE FOR DETAILS
The above diagram is available in two formats to facilitate printing and viewing.
Adobe acrobat version (Acobat Reader required) or 1790x2430 121k landscape GIF
Note: Radio Shack no longer carries the 274-201 connector shown in the drawing. However, the Cinch P-302-CCT is available from DeMar Electronics, PO Box 7215, Algonquin, IL 60102, (877) 655-6433. They are listed in their on line catalog at http://DeMarElectronics.com/. DeMar Electronics is a frequent advertiser in Model Railroader. This notice is informational only and is not an endorsement of DeMar Electronics. - 4/28/2003
Use #22 to #24 ga solid wire soldered to the outside of rails for connection to track power leads. "Solder terminal Strips" make an easy to trouble shoot connection point. Use as many power feeds per tracks as needed.
NOTE: A single large power supply is used with the many throttles on large layouts. The three tracks MUST NOT have any common connection. DO NOT use "COMMON RAIL" wiring. Gaps must be used on both rails on any crossover tracks. If the three main tracks are part of a yard, it must be possible to isolate them electrically.
Use UL approved heavy duty, multi outlet, extension unit with a grounded (three wire) power cord, 14 ga wire, 15 amp capacity. Use Stanley 1-1/4" Safetycup Hooks #V8482 to retain cord. Unit must be removable to meet safety codes, Wiring is subject to inspection by safety officials at public gatherings. if built in, 110V wiring must meet National Electric Code for Temporary Wiring, or any stricter local codes.
NOTE: For safety, a GFI (Ground Fault interrupter) circuit breaker is recommended in the 110 line powering a layout.